TDC Mezzanine Card
As tracks pass through each layer of the COT, they generate “hits” at each of the 12 wire-layers within a superlayer.
The mezzanine card is responsible
for classifying each hit on a wire
- Prompt: Drift time from 0-44 nsec
- Delayed: Drift time from 45-132nsec